Description
Advantages and Features Introduction:
- It adopts the existing 7~10℃ ice water in the factory, utilizes the ice water to exchange heat with compressed air, eliminating the need for a refrigerant compressor, saving power and being environmentally friendly.
- This equipment adopts a dual-tube dual-cooling system, dual cyclone and stainless steel mesh filtration for water removal, enabling efficient filtration and water removal.
- This equipment adopts a counter-flow air heat exchange system with a large heat exchange area, higher energy recovery rate, and reduced energy consumption.
- The evaporator of this equipment is designed to be withdrawable, which facilitates cleaning after scaling, making maintenance and servicing more convenient.
- This equipment cancels the traditional externally added cyclone separator and adopts an outer cylinder design. The dual heat exchange system is equipped with a wave-type cyclone and stainless steel mesh filtration for efficient water removal.
- The whole machine of this equipment has no elbow design, which effectively reduces pressure drop. The overall machine pressure drop can be as low as ≤0.015MPa, while the traditional machine pressure drop is 0.035MPa, effectively reducing the power consumption of the air compressor and saving costs for users.
- The equipment has a low failure rate, requires no servicing and maintenance, saving labor costs.
- This equipment is equipped with an air inlet pressure gauge and an outlet pressure gauge, which can monitor the pressure drop status at any time. It is also equipped with a cooling water pressure gauge to monitor the cooling water pressure status.
- This equipment is equipped with an inlet temperature display, an outlet temperature display, a cooling water inlet temperature display and a cooling water outlet temperature display, which can monitor the operating status of the machine at any time.
- This equipment is designed with a dual water pump configuration, with one in use and one as a backup, ensuring the normal operation of the cooling water.
- The equipment has a small size and is easy to install. It is available in two designs: naked machine without a cabinet and with a cabinet. The filter is an optional accessory configured according to customer needs.
Working Principle:
It adopts technologies such as dual-system high-efficiency heat exchange, counter-flow heat exchange, and ultra-efficient gas-liquid separation to achieve cold and hot exchange for water removal.
Dynamic Ice-Water Type Drying and Filtering Unit System Model
| Model | Air Processing Capacity (m³/min) | Design Pressure (Mpa) | Inlet/Outlet Gas Diameter of Condensation Separation System | Inlet/Outlet Water Diameter of Condensation Separation System | Pump Power (kw) | Ice-Water Machine Power (HP)/Interface | Water Tank (T) | Cooling Water Tower (T/H) | Remarks |
|---|---|---|---|---|---|---|---|---|---|
| HR-40SD | 40 | 0.7-1.0 | DN100 | DN40 | 0.75 | 3/G1 | 1.5 | 40T | 1) This design is a no-elbow design, with pressure drop ≤0.015MPa |
| HR-60SD | 60 | 0.7-1.0 | DN125 | DN40 | 0.75 | 3/G1 | 1.5 | 40T | 2) This cooler is a dual-system temperature reduction heat exchange system, with dual-stage dual-system cyclone separation + stainless steel mesh filtration for water removal |
| HR-80SD | 80 | 0.7-1.0 | DN150 | DN40 | 0.75 | 3/G1 | 1.5 | 40T | 3) Single-stage filter |
| HR-100SD | 100 | 0.7-1.0 | DN200 | DN50 | 1.5 | 5/G1.5 | 2 | 50T | |
| HR-120SD | 120 | 0.7-1.0 | DN200 | DN50 | 1.5 | 5/G1.5 | 2 | 50T | |
| HR-150SD | 150 | 0.7-1.0 | DN200 | DN50 | 1.5 | 5/G1.5 | 2 | 60T | |
| HR-200SD | 200 | 0.7-1.0 | DN250 | DN65 | 2.2 | 5/G1.5 | 3 | 80T | |
| HR-250SD | 250 | 0.7-1.0 | DN250 | DN65 | 2.2 | 5/G1.5 | 3 | 80T | |
| HR-300SD | 300 | 0.7-1.0 | DN250 | DN65 | 2.2 | 5/G1.5 | 3 | 100T |
Remarks
If there are any changes in the model, specifications, or color, we will not notify separately. The actual product shall prevail.